Search results

UKworkshop.co.uk

Help Support UKworkshop.co.uk:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. O

    Adams Workshop Build Thread.... got walls & a roof!!!

    The regulations came about because people were plugging in electric mowers through the window to the kitchen or into the garage etc when they cut the cable with the mower and got injured they changed the regulations ,to make any place you can plug a external device (mower) protected by a fixed...
  2. O

    Glue line on router table - again

    Why not use a straight router bit and set the table split fences as a vertical plainer in and out feed so you then have a jointer but you push the timber across the table obviously capacity is a problem but ok for edge jointing
  3. O

    Fox F14-655 1HP Morticer

    Fox mortiser is copy of delta this is a 1" m/c. My fox is 5/8 and came with chisels which are just ok ,machine is good just tighten chuck hard or auger will move lots of stroke and adjustments gets good reviews.
  4. O

    Mikes New Workshop thread --- I hope somebody's interested

    Might be worth thinking about where you are going to have your benches +tables+ cupboards and how you secure them they may do the job for you with some careful design and layout.
  5. O

    What sawbench now

    The 12 inch SIP gets good reports ebay link
  6. O

    Dust Extraction Solution Adviceq

    100mm pipe plumbing is expensive i have one outlet adj. to the double doors ( to get the max board length )with long flex to connect to p/t bandsaw and norms router table all are on casters . I use the SIP extractor in a separate external enclosure short pipe run, which is sized to allow for the...
  7. O

    Compressor and Air Tool Oil

    Toolstation can supply both.
  8. O

    New Mag.

    Found this on webbhttp://www.thegmcgroup.com/item--Woodworking-Plans-and-Projects--1013WP.html
  9. O

    what would you do?

    Get broadband lots of deals about .
  10. O

    Workshop question

    From the roof line i think you have three A frames the space between i call a bent and is where extra frames could be required.A structural engineer or maybe the person that draws up construction plans for approval could design and do calculations for you or you could copy another buildings...
  11. O

    Making a hoover/extraction

    I think it would be better to have the filter on the air in side of the fan like a shop vac. or clogging of the motor and fan will occur
  12. O

    Workshop question

    From the pictures its just maintenance work getting it watertight and diverting any water coming down the hill away the floor cracks are very fine it all will need drying out no major reconstruction. The A frames were designed to minimise the use of wood and stop the walls spreading under the...
  13. O

    Loft flooring question

    Difficult to say i think you will have to monitor over time. Redrilling the screw holes oversize and provision of expansion gap in the chipboard should deal with it if required.
  14. O

    The Beast has landed.

    Jake & Davy thanks i understand now.
  15. O

    The Beast has landed.

    I am still in difficulty the ring is rated at 32amps the sockets are part of it so which bit of the socket cannot stand the current just can not get my head round it sorry.
  16. O

    Workshop question

    The dimpled membrane would have to have a screed or it will be crushed on a floor so height problem. Get the building dry then tape a sheet one sq metre of clear poly. to the floor a small amount of moisture trapped in a week and you can consider poly sheet and chipboard any more and it will...
  17. O

    The Beast has landed.

    Sorry i can not under stand the above a ring main has two cables 1 clockwise &1 anti clock both rated at 30amps when you plug some thing in the current is shared between clock and anti clock and the ring is protected by a 32 amp mcb so how can you overload it, it is overrated for its purpose so...
  18. O

    Workshop question

    What ever happens you need to get the hen house dry so low cost work :-sort out the gutters get the rain caught and taken away. Is the surrounding ground to high allowing the rain to splash the structure (could be the source of rotting walls)and also make floor wet, dig it out or dig a channel...
  19. O

    The Beast has landed.

    I agree with Sawdust and i also have one of these machines its always worked fine on 13amp it must have been switched a few hundred times since i got it . By the way p/t make lots of planeings which if not removed get in the rollers and can be pressed into the wood and obviously clog up the...
  20. O

    The Beast has landed.

    The m/c works on 13amp supply so you need 3 core flex 2.5mm if lead is to be longer than 10meter but 2.5 probably better any way .Its not polarised so wire the earth to the metal strip and power to sockets . Paul O has it wrong a 16 amp supply is not required.
Back
Top